Three Phase Chassis Type (012 JK)
Salient Features
- Isolation 2500VAC
- Voltage Range 50 to 480 Vac
- Load Current 3x10A/16A/25A/40A
- Reverse Polarity Protection
Electrical Specification @ TA = 25ºC
Electrical Specifications
|
Product Part Numbers
|
Parameter
|
Symbol
|
Unit
|
012 JDA 481000
|
012 JDA 481600 |
012 JDA 482500 |
012 JDA 484000 |
Control voltage range
|
|
Vdc
|
3-32
|
3-32 |
3-32 |
3-32 |
Control current range
|
|
mA
|
80
|
80 |
80 |
80 |
Pick-up voltage
|
|
Vdc
|
3.0
|
3.0 |
3.0 |
3.0 |
Drop-out voltage
|
|
Vdc
|
1.0
|
1.0
|
1.0
|
1.0
|
Input resistance
|
|
|
Current regulator
|
Current regulator |
Current regulator |
Current regulator |
RMS on state current
|
lT
|
A
|
10
|
16
|
25
|
40
|
Mains control volt
|
Vdrm |
Vac
|
50-480
|
50-480 |
50-480 |
50-480 |
Peak off state voltage
|
Vdrm
|
Vpk
|
800~1200
|
800~1200
|
800~1200
|
800~1200
|
Zero turn-on voltage
|
|
Vpk
|
20
|
20
|
20
|
20
|
On-state voltage drop
|
Vw
|
Vac
|
1.6
|
1.6 |
1.85 |
1.85 |
Off-state leakage current
|
Idrm
|
mA
|
10
|
10
|
10
|
10
|
Peak one cycle surge Current (Non-Rep)
|
lTSm
|
A
|
100
|
160
|
250
|
350
|
Holding current
|
lH
|
mA
|
150
|
150
|
250
|
250
|
Critical rate of rise of off state voltage
|
dv/dt
|
V/µs
|
200
|
200
|
250
|
250
|
Thermal resistance
|
R
|
°C/W
|
3.5
|
2.5
|
1.5
|
1.0
|
Frequency range
|
F
|
Hz
|
47~63
|
47~63 |
47~63 |
47~63 |
Operating temperature
|
T-open
|
°C |
-30 to + 80 |
-30 to + 80 |
-30 to + 80 |
-30 to + 80 |
Turn-on
|
T-on
|
ms
|
10
|
10
|
10
|
10
|
| Turn-off |
T-off
|
ms
|
10
|
10
|
10
|
10
|
Fusing current
|
1²1
|
A²S
|
50
|
120
|
260
|
610
|
|